Gorgy Time · Time servers

LEDI® NETWORK ATS

Redundant-power NTP/SNTP time server

Manufacturer product images · for reference

LEDI® NETWORK ATS — manufacturer product image

Time servers

Technical specifications
BrandGorgy Time
CategoryTime servers
Key featuresNTP/SNTP output included by default on RJ45; Power Supply Redundancy 18-36 or 36-72 VDC with 110-250 VAC; Configurable priorities of synchronization inputs; Compensation of input delay due to transmission distance and threshold setting for security; Time Base and algorithm ensuring output accuracy up to 50ns when synchronized to GPS/GNSS; Independence and modularity of output boards; PPS and 10Mhz output (available with OCXO oscillator only) via BNC connectors; Alarm management via SNMP TRAP (V1, V2C, V3) and two static relay outputs on screw terminal for synchronization and power supply alarms; Manual or automatic adjustment for transmission delay; Local or UTC time display on front panel; Internal Temperature monitoring (°C)
GNSS Antenna (option)For more information on our GNSS antennas, refer to the technical specifications (see reference table 92225/)
Configuration featuresRemote Configuration and time setting via embedded web interface; IP Configuration by front panel keyboard; Configuration file can be retrieved and uploaded via secured web interface; Activating and deactivating configurations; Auto-IP v4
Specifications - Weight2,3 kg
Synchronization outputsMultiple outputs (see reference table 92167/); NTP/SNTP output included by default on RJ45; PPS and 10Mhz output (available with OCXO oscillator only) via BNC connectors; NB: The RJ45 ports of the optional NTP outputs are independent and isolated by means of protocol break.
Specifications - DisplayOrange OLED screen with backlight
Specifications - MTBF/MTTRMother board: 139 000 h / 10 min Display board: 151 000 h / 5min Output board: 128 000 h / 5min
Internal Time Base - Ageing5.10-11 month
Specifications - Dimensions1U Rack 482 x 44 x 285 mm (LxHxD)
Specifications - Power CableIEC 60320 defined C13 / MALE SCHUKO 2 (EUROPE) & (Type F)*
Specifications - Power supply110-250VAC 1,4 A max. 50/60Hz - type IEC 60320 defined C14 and 18-36 VDC or 36 - 72 VDC - 2 points screw terminal block
Security and network protocolsBackup of configuration setting in flash memory; Supervision via SNMP V3 or supervision software GT SCADA or Syslog; Remote configuration via secured web page; Configuration setting command prompt via SSH; Firmware update via FTP or SCP; Compatible IP v4/v6 (compatible DHCP v4/v6); Configuration on Web interface via HTTP et HTTP(s); Secure access to web interface by identifier and password; Authentication protocol and MD5 encryption; Network communication ports can be disabled; PTPv2 IEEE 1588 (TELECOM, ENERGIE profiles)
Specifications - CertificationsCE, EN62368 (safety), EN 55032 (EMC transmission), EN 55035 (EMC immunity), ROHS
Specifications - Maximal Consumption45 VA (Rubidium version) at start 25 VA in operation between 10 and 30 °C
Specifications - Storage temperature-20 to 70°C
Internal Time Base - Max. consumption40W
Specifications - Telecom certificationsG.811 and G.812 Compatible
Specifications - Temperature in operation-10 to 50°C
Specifications - Shock and vibration testsMIL STD 810 G
Internal Time Base - Vibration in operationGR-CORE-63, Section 5.4.2 Random et Sinusoïdal MIL-PRF-28800F, Class 3, 4 / MIL-STD-810F, 514.5 Method, Category 24 Average acceleration: 7,7g rms duration: 1 h/axis Axis: X/Y/Z axis
Synchronization inputs - 3rd reference input (backup)PPS input Frequency input (between 1kHz and 10MHz)
Internal Time Base - Frequency stability (Allan Deviation)Up to 3.10-12
Synchronization inputs - 1st time reference input (at choice)Multi-constellation GNSS Receiver: (GPS, GLONASS, BEIDOU, GALILEO) or GPS. Cold start: accuracy 10 to 50 ns
Synchronization inputs - 2nd time reference input (at choice)NTPv4 Ethernet 10/100BaseT- RJ45 input PTPv2 (IEEE 1588) ASCII (NMEA 0183 RMC or ZDA by auto-detection) + TOP
Internal Time Base - Time drift (without synchronization over 180 days)< 10 msec
Internal Time Base - Frequency stability in T° between -20°C and +60°C1.10-10