Gorgy Time · Time servers

LEDI® NETWORK ITS V2M 2U

2U rack-mount NTP time server

Manufacturer product images · for reference

LEDI® NETWORK ITS V2M 2U — manufacturer product image

Time servers

Technical specifications
BrandGorgy Time
CategoryTime servers
Specifications - IP31
Specifications - MTBF110 000 h
Configuration - Auto-IPv4
Specifications - Weight2,3 kg
Specifications - DisplayOrange OLED screen with backlight
Specifications - Dimensions19" 2U Rack. 482x88x266 mm (LxHxD)
Specifications - Power CableIEC 60320 defined C13 / MALE SCHUKO 2 (EUROPE) & (Type F)*
Specifications - Power supply110-250VAC – 1,4 A max. 50/60Hz - type IEC 60320 defined C14 and 18 - 36 VDC or 36 - 72 VDC - 2 points screw terminal block
Key features - NTP/SNTP outputincluded by default on RJ45
Key features - Alarm managementvia SNMP TRAP (V1, V2C, V3) and two static relay outputs on screw terminal for synchronization and power supply alarms
Specifications - CertificationsCE, EN62368 (safety), EN 55032 (EMC transmission), EN 55035 (EMC immunity), ROHS
Configuration - IP Configurationby front panel keyboard
Configuration - Configuration filecan be retrieved and uploaded via secured web interface
Internal Time Base - Ageing (OCXO)5.10-10 / day
Internal Time Base - Ageing (TCXO)2.10-9 / day
GNSS Antenna (option) - InformationFor more information on our GNSS antennas, refer to the technical specifications (see reference table 92225/)
Key features - PPS and 10Mhz output(available with OCXO oscillator only) via BNC connectors
Specifications - MTTR - Mother board10 min
Specifications - MTTR - Output board5 min
Specifications - Maximal Consumption20 VA
Internal Time Base - Ageing (OCXO LN)3.10-10 / day
Specifications - MTTR - Display board5 min
Key features - Power Supply Redundancy18-36 or 36-72 VDC with 110-250 VAC
Key features - Time Base and algorithmensuring output accuracy up to 50ns when synchronized to GPS/GNSS
Key features - Local or UTC time displayon front panel
Synchronization outputs - NTP/SNTP outputincluded by default on RJ45
Key features - Compensation of input delaydue to transmission distance and threshold setting for security
Key features - Independence and modularityof output boards
Synchronization outputs - Multiple outputsMultiple outputs
Security and network protocols - Supervisionvia SNMP V3 or supervision software GT SCADA or Syslog
Synchronization outputs - Note on RJ45 portsThe RJ45 ports of the optional NTP outputs are independent and isolated by means of protocol break.
Configuration - Automatic Time offset and DSTon outputs
Key features - Manual or automatic adjustmentfor transmission delay
Security and network protocols - Compatible IPv4/v6 (compatible DHCP v4/6)
Synchronization outputs - PPS and 10Mhz output(available with OCXO oscillator only) via BNC connectors
Internal Time Base - frequency stability (OCXO)1.10-9 (-20°C à 70°C)
Internal Time Base - frequency stability (TCXO)1.10-6 (0°C à 60°C)
Security and network protocols - Firmware updatevia FTP or SCP
Specifications - Storage temperature / hygrometry-20 to 70°C / 10 to 85% HR
Internal Time Base - frequency stability (OCXO LN)5.10-10 (-10°C à 60°C)
Specifications - Maximum operating/storage altitude3 500 m (11 483 ft)
Specifications - Operating Temperature / hygrometry-20 à 50°C/ 0 à 90% HR
Security and network protocols - Basic power reserveincluded by default. Possibility of extending the duration. Duration varies depending on the options chosen, contact us for more details.
Configuration - Remote Configuration and time settingvia embedded web interface
Security and network protocols - Remote configurationvia secured web page
Synchronization inputs - 3rd reference input (backup)Frequency input (between 1kHz and 10MHz)
Security and network protocols - Authentication protocoland MD5 encryption
Storage Conditions - Normal (10°C to 40°C) - Hygrometry10 to 85% HR
Storage Conditions - Extreme (-20°C to 0°C) - Hygrometry10 to 85% HR
Storage Conditions - Extreme (40°C to 70°C) - Hygrometry10 to 85% HR
Security and network protocols - Network communication portscan be disabled
Synchronization inputs - 1st time reference input (at choice)Multi-constellation GNSS Receiver: (GPS, GLONASS, BEIDOU, GALILEO) or GPS; Cold start, accuracy 10 to 50 ns; Cold start, précision 10 à 50 ns ASCII (NMEA 0183 RMC or ZDA by auto-detection) + TOP PPS input
Synchronization inputs - 2nd time reference input (at choice)AFNOR NFS 87-500/IRIG B/ IEEE1344 NTP (V2, V3, V4) 10/100BaseT
Security and network protocols - Configuration on Web interfacevia HTTP et HTTP(s)
Security and network protocols - Secure access to web interfaceby identifier and password
Key features - Configurable priorities of synchronization inputsConfigurable priorities of synchronization inputs
Security and network protocols - Backup of configuration settingin flash memory
Security and network protocols - Configuration setting command promptvia SSH
Storage Conditions - Normal (10°C to 40°C) - Maximum cumulated duration6 months
Storage Conditions - Extreme (-20°C to 0°C) - Maximum cumulated duration48h
Storage Conditions - Extreme (40°C to 70°C) - Maximum cumulated duration48h

Product information and images are compiled from the manufacturer's own publications; they do not depict a Sedan Mühendislik installation. Technical data is confirmed before ordering.

From the same category

Time servers

The full category — 22 products

Quote

Send your dial count and floor plan

The number of dials, the indoor/outdoor split and whether a master clock already exists — those three are enough. We come back with the system design and the price.