Gorgy Time · Time servers

LEDI® NETWORK TS

NTP time server with LCD display

Manufacturer product images · for reference

LEDI® NETWORK TS — manufacturer product image

Time servers

Technical specifications
BrandGorgy Time
CategoryTime servers
MTBF120 000 h
Display4 x 20 character LCD display with blue backlight
Power supply110-250 VAC – 50/60Hz or 36-72 VDC - 2 points screw terminal block
CertificationsCE, EN 62368 (Safety), EN 55032 (EMC transmission), EN 55034 (EMC immunity), ROHS
Dimensions Rack19" 1U
Power Cable typeIEC 60320 defined C14 / IEC 60320 defined C13 / MALE SCHUKO 2 (EUROPE) & (Type F)*
MTTR Mother board10 min
MTTR Output board5 min
Dimensions (LxHxD)482x44x266 mm
MTTR Display board5 min
Maximal Consumption20 VA
Synchronization input 1DCF 77kHz (Europe)
Synchronization input 2NTP 10/100 base T
Synchronization input 3GPS (Accuracy < 100 ns)
Synchronization input 4GPS converter (3Gxx) (Accuracy < 1 µs)
Synchronization input 5AFNOR NFS 87-500 / IRIG B
Synchronization outputs 1AFNOR NFS 87-500/IRIG B modulated (Accuracy < 20 µs)
Synchronization outputs 2DCLS AFNOR NFS 87-500 / IRIG B (TTL/RS 422) (Accuracy < 10µs)
Synchronization outputs 3NTP/SNTP (V2, V3, V4) (Accuracy < 50 µs)
Synchronization outputs 4ASCII RS485 + TOP
Synchronization outputs 5ASCII RS232 + TOP
Synchronization outputs 6Tops 1000 Hz
Synchronization outputs 7Alarms (synchronization and power default)
Synchronization outputs 8SMPTE/EBU
Synchronization outputs 9Pulse or DCF24v
Internal Time Base TCXO Ageing1,5.10-9 / day
Weight (standard configuration)2,3 kg
Storage temperature / hygrometry-20 to 70°C / 10 to 85% HR
Operating Temperature / hygrometry-20 to 50°C / max 90% HR (without condensing)
Storage Conditions Normal Hygrometry10 to 85% HR
Storage Conditions Normal Temperature10°C to 40°C
Storage Conditions Extreme Hygrometry 110 to 85% HR
Storage Conditions Extreme Hygrometry 210 to 85% HR
Storage Conditions Extreme Temperature 1-20°C to 0°C
Storage Conditions Extreme Temperature 240°C to 70°C
Internal Time Base TCXO Frequency stability2.10-8 (0°C à 60°C)
Storage Conditions Normal Maximum cumulated duration6 months
Storage Conditions Extreme Maximum cumulated duration 148h
Storage Conditions Extreme Maximum cumulated duration 248h